Multi - Layer Insulation (MLI) is a special type of high performance thermal insulation system that
is utilized on various
spacecraft, satellites and probes. It consists of alternating layers of
a
metallized polymer film such
as "Aluminized" Mylar and a low conductivity spacer material like
Dacron. The reflective film
layers effectively act as radiation shields, preventing radiant energy
from penetrating the MLI.
The spacer which has a netting pattern ensures that no additional
heat is
transferred through solid conduction. However, at a certain pressure level, gaseous conduction
and convection start to become significant and could dominate radiation heat transfer.
Thus, it is important to keep track of the pressure in the interstitial region between layers.
The goal of this project is to design and implement
a compact pressure sensor to fit between layers of MLI.
It is expected that the
sensor can measure a large pressure range all the way from atmospheric
(101 kPa) to
roughly vacuum pressures
(10^-2 Pa). The requirements set forth by our sponsor are that the
sensor is minimally
invasive to the MLI's
structure, and that it can operate in a temperature range of 77 K to
300 K. The desired
sampling rate is 1 sample
per second. Another main objective of this project is to minimize the
power
consumption and heat produced by the device.
Conceptual designs
1. The first proposed idea is a variable capacitor that changes its capacitance based on an external pressure change.
The bottom plate of the
capacitor is stationary and the top surface is a flexible diaphragm. It
is doped with various
elements (like germanium and silicon) to increase strength and flexibility.
2. The second idea is an extension of
the first. The Multi-Stage Capacitor would be able to read a low and a
high
pressure range based on the stiffness of the red and yellow diaphragm.
3. The fiber optic design is by far
the most versatile because it can measure a very large range of
pressures and is
useful
even in rugged and low-temperature environments. A light source sends a
signal down a fiber-optic cable where
the intensity of the
light reflected off a diaphragm is measured and compared to the
original intensity and correlated
to pressure.
Polarization, Wavelength Change and the Phase Angle are parameters that
can be related to pressure
instead of light intensity.